Step3
Drill Hole for Line Set etc
Remove mounting bracket from the rear of the Indoor unit,
use a Phillips head screwdriver to remove the unit pipe strap, and if
unit is a heat pump the defrost sensor also must be undone from its
retainer. If mounting the unit on an outside wall measure from the
edges of the unit to the center of the line set stub 90° bend to locate the
the center of the wall penetration. Drill a ø 3" hole through the wall
Angle the wall penetration slightly down towards the outside to
assist in draining the condensate away from the unit
If mounting the unit on an inside wall, use the knockouts provided on the LHS and RHS of the unit to route the
piping and wiring connections through
Step 4
Install Mounting Bracket
Locate and secure the mounting bracket to the wall, the Indoor unit
weighs a maximum of 20Lbs, use wall anchors and mount to a wall stud
to ensure that the wall is capable of holding the weight of the unit
Use a level to ensure mounting bracket is leveled, so condensate can
drain properly
Step 5
Prepare Unit Line Set Connections
Rotate refrigerant line stubs set gently through 90° (if mounting on an outside wall), for other line set
configurations align the stubs as required
Tip : Use Duct tape to tape the Condensate hose (make sure it is below the Line set stubs) and the Defrost
Sensor (Heat Pump Only), this makes it easier to guide them though the hole drilled in the wall
Also if possible feed the 14 AWG Interconnect wiring between Indoor and Outdoor (Maximum # of
wires required is 6) through the unit electrical connection (if required by local codes an electrical connector
can be attached to the rear of the unit). Tape the loose wire to the line set stubs.
These two tips save time and prevent damage to the stubs when mounting the Indoor unit
Note :
Condensate hose is taped below line set stubs
Wrap Duct tape to the end of the condensate hose for easier
installation
Installation and Maintenance Manual