Step 6
Install unit on Mounting Bracket
Feed the line set stubs/condensate hose/wiring connections through
the ø 3" hole, then locate the unit key slots onto the tabs on top of
the mounting bracket. Bottom of the unit then latches onto the
mounting bracket. Indoor unit is now installed, it should be plumb,
level and flush with the wall. If it is not check that the line set stubs
are completely through the wall penetration, and also that the wall is plumb
Step 7
Locate Outdoor unit
Clearances for the Outdoor unit are :
6" Minimum Install the Outdoor
unit on a Condenser
Service Pad or if a Heat
Valves Pump use feet to
6" 12" raise unit up approx
Minimum Minimum 6" to allow for
defrost to drain away
24" Minimum
Do not install the Outdoor unit in a location exposed to high winds (field fabricated and installed wind baffle
may be required).
Ensure location does not impede access around unit and pose a disturbance to neighboring areas
Step 8
Refrigerant Line Set Piping
Interconnecting line set between the Outdoor unit and the Indoor unit, must have both refrigerant lines
insulated as condensing device is located in the Outdoor unit
Gently bend the line set stubs from the Indoor unit to the desired location
Using 2 x 10"/12" Crescent wrenches remove the flare nuts from the Indoor unit line stubs. Unit is filled with
a dry gas, check for release of this to ensure that no leaks are present
Use a small amount of vacuum pump oil on the male flare threads to ease installation. Connect the line set to
the stubs. Using the 2 wrenches, 1 on the male & 1 on the female tighten the flare nuts
DO NOT INSTALL A LIQUID LINE SIGHT GLASS OR FILTER DRIER IN THE SYSTEM
Run the line set to the Outdoor unit, avoid tight bends and kinking the lines. Quietside does not recommend
brazing line sets together or to the unit connections
If line set length is in excess of that required, cut line set and re-flare or coil excess vertically to facilitate oil
return to the compressor
Installing the
Line Set on the
Indoor unit
stubs
Installation and Maintenance Manual
Unit Installation (Cont)
Outdoor Unit Rear
Front Condenser Fan
Line Set Connections
under the GRAY caps